| Calibration Substrate Selection Guide |
| Calibration |
Pad Size(microns) |
Calibration |
Footprint |
Pitch Range |
Pitch Range |
| Substrate |
Types Supported |
Recommeded (µm) |
Acceptable (µm) |
| CS-5 |
50 x 50 |
SOLT, LRL, LRM |
GSG |
75 - 250 |
75 - 250 |
| CS-9 |
100 x 100 |
SOLT, LRL, LRM |
GSG |
250 - 600 |
150 - 600 |
| CS-10 |
150 x 150 |
SOLT, LRM |
GSG |
600 -1250 |
225 -1250 |
| CS-18 |
300 x 300 |
SOLT, LRM |
GSG |
1250 - 2540 |
500 - 2540 |
| Figure 2 |
| CS-8 |
50 x 50 |
SOLT, LRM |
GS, SG |
50 - 200 |
50 - 300 |
| 100 x 100 |
| 150 x 150 |
| CS-14 |
100 x 100 |
SOLT, LRM |
GS, SG |
200 - 400 |
150 - 600 |
| CS-11 |
150 x 150 |
SOLT, LRM |
GS, SG |
400 - 1250 |
175 - 1250 |
| CS-17 |
300x300 |
SOLT, LRM |
GS, SG |
750-2540 |
450-2540 |
| Figure 3 |
| Special Calibration Substrate Designed For Use Above 110 GHz |
| CS-15 |
25 x 25 |
SOLT, LRL, LRM |
GSG |
40 - 150 (SOLT) |
40 - 150 |
| 30 - 150 |
| (LRL) |
| Table 3 |
| SOLT = Short-Open-Load-Through |
| LRL = Line-Reflect-Line (Which is equivalent to TRL = Through-Reflect-Line) |
| LRM = Line-Reflect-Match (Which is equivalent to TRM = Through-Reflect-Match) |
| |
|
|
|
|
|
|
| Accurate, easy to use calibration substrates, calibration coefficients, and detailed instructions allow you to precisely calibrate the measurement system to the probe tips. |
|
| |
|
| The typical elements for calibrating a microwave measurement system consists of opens, shorts, 50 ohm loads, and throughs. Precision crafted calibration substrates, when properly used, assure you of accurate on-wafer test results. |
|
| |
|
| All load standards are individually inspected and trimmed to within 0.25% accuracy using NIST traceable equipment. |
|
| |
|
| Easy to use step by step instructions are provided for use with Agilent ENA four port network analyzers and Agilent PNA network analyzers with PLTS software. |
|
| Differential Calibration Substrate Selection Guide |
|
| Calibration |
Pad Size (microns) |
Calibration |
Footprint |
Pitch |
|
| Substrate |
Types Supported |
|
| CS-2100 |
50 x 50 |
SOLT, LRL, LRM |
GSGSG |
100 |
|
| CS-2125 |
50 x 50 |
SOLT, LRL, LRM |
GSGSG |
125 |
|
| CS-2150 |
50 x 50 |
SOLT, LRL, LRM |
GSGSG |
150 |
|
| CS-2200 |
50 x 50 |
SOLT, LRL, LRM |
GSGSG |
200 |
|
| CS-2250 |
50 x 50 |
SOLT, LRL, LRM |
GSGSG |
250 |
|
| CS-2500 |
100 x 100 |
SOLT, LRL, LRM |
GSGSG |
500 |
|
| Figure 2 |
|
| CS-3100 |
50 x 50 |
SOLT, LRM |
GSSG |
100 |
|
| CS-3125 |
50 x 50 |
SOLT, LRM |
GSSG |
125 |
|
| CS-3150 |
50 x 50 |
SOLT, LRM |
GSSG |
150 |
|
| CS-3200 |
50 x 50 |
SOLT, LRM |
GSSG |
200 |
|
| CS-3250 |
50 x 50 |
SOLT, LRM |
GSSG |
250 |
|
| CS-3450 |
100 x 100 |
SOLT, LRM |
GSSG |
450 |
|
| CS-3500 |
150 x 150 |
SOLT, LRM |
GSSG |
500 |
|
| CS-3600 |
100 x 100 |
SOLT, LRM |
GSSG |
600 |
|
| CS-3800 |
300 x 300 |
SOLT, LRM |
GSSG |
800 |
|
| CS-31000 |
300 x 300 |
SOLT, LRM |
GSSG |
1000 |
|
| CS-31250 |
300 x 300 |
SOLT, LRM |
GSSG |
1250 |
|
| Figure 3 |
|
| SOLT = Short-Open-Load-Through |
|
| LRL = Line-Reflect-Line |
|
| LRM = Line-Reflect-Match |
|